We use cookies to improve your browsing experience. By continuing to use our site, you accept our cookie policy.

close Close Cookie Notification
Instron
  • Back
  • Home
  • Produkty
    Urządzenia testujące
    Maszyny Wytrzymałościowe - Zrywarki
    Wytrzymałość strukturalna
    Automatyczne systemy testujące
    Dynamiczne i zmęczeniowe systemy testujące
    Symulatory zderzeń
    Testery skręcania
    Reometry i Plastometry (MFT)
    Młoty zrzutowe i młoty wahadłowe
    HDT i Vicat
    Produkty poprzednich generacji
    AKCESORIA
    Oprogramowanie
    Głowice pomiarowe
    Oddzieranie, tarcie, przebicie
    Komory temperaturowe i Piece
    Uchwyty do rozciągania
    Uchwyty do badania ugięcia
    Płyty kompresyjne
    Systemy i akcesoria biomedyczne
    Ekstensometry
    Composite Fixtures
    Uchwyty do badania elektroniki
    Pomiary i przygotowanie próbek
    All Accessories
    Katalog akcesoriów
  • Rozwiązania branżowe
    Search by Material Search by Standard Search by Test Type
    Industries
    Automotive
    Biomedical
    Electronics
    Materials
    Composites
    Metals
    Plastics
  • Serwis i wsparcie
    Instron Remote Technical Support CYKL ŻYCIA PRODUKTU Historie serwisowe Szkolenia
    USŁUGI
    Kalibracja i weryfikacja
    Usługi wdrożeniowe Instron
    Instalacja i przeniesienie
    WSPARCIE TECHNICZNE
    FAQ Często zadawane pytania
    Usługi aktualizacji oprogramowania
    ZASOBY
    Instrukcje
    Lokalizator numerów seryjnych
  • Nasza firma
    KARIERA Informacje prasowe NEWSLETTERY
    O NAS
    Nasza historia
    Lokalizacje
    Akredytacje i certyfikaty
    ZASOBY
    Słownik
    Typy testów
    Biuletyny
    Literatura
    Aktualności
    Poradnik
    Webinaria
    Studia przypadku
  • Skontaktuj się z nami
  • Polska
Testing Solutions » By Standard » Others » EN 1719

EN 1719 Loop Tack of Pressure Sensitive Adhesives

Standard

  • EN 1719

Specimen

  • Pętla

Materials

  • Kleje

Test Types

  • Zdzieranie, rozrywanie i tarcie
  • Rozciąganie
Contact usView Accessories Catalog
  • Description
  • Literature

BS EN 1719 determines the “loop tack” measurement for coated pressure-sensitive adhesives.  Adhesive strips are formed into a loop and gripped together.  The adhesive loop is brought down into contact with a flat rigid plate at a rate of 5 mm/s.  When the loop contacts the plate over approximately 25 mm by 25 mm, the adhesive loop is pulled upwards at a rate of 5 mm/s and the maximum force to fully separate the loop from the plate is recorded.

The challenges of testing to this standard are:
  • Reporting calculations in compliance with the standard
  • Data rate used to capture the maximum peak
  • Eliminating slippage throughout the test

Instron Solution:

  • Reporting calculations in compliance with the standard – Bluehill® Universal comes with pre-configured test methods and supporting documentation to ensure that you are testing according to BS EN 1719.
  • Data rate used to capture the maximum peak – Instron’s 5900 series frames enable data capture of up to 2.5 kHz to ensure that all fast changing test events are captured.  Too low of a bandwidth may “dull” the system and lead to a missed peak, resulting in lower loop tack values. 
  • Eliminating slippage throughout the test – The pneumatic and advanced screw action grips employ a patented “quick-change” jaw face design which enables operators to easily change jaw faces to accommodate the needs of their materials.  

It is important to review BS EN 1719:1999 in order to fully understand the test setup, procedure, and results requirements.


5900 Series Premier Testing Systems Brochure

5900 Universal Testing Systems are engineered for precision, built for durability, and offer the flexibility for changing requirements. They are designed with standard and optional features that increase testing efficiency and improve the testing experience for the operator. A wide range of models are available for testing capacities from < 100N up to 600kN.

  • Products
  • 1/22/2019
  • 6.8 MB

2712 Series Pneumatic Side Action Grips (2712-041, 2712-042, 2712-045, 2712-046)

Instron® 2712-04x Series Pneumatic grips, packed with features to enhance gripping performance, usability, and operator safety.

  • Products
  • 5/16/2019
  • 0.7 MB

2710-100 Series Screw Side-Action Grips

Screw side-action grips provide a very simple and efficient method for holding test specimens in a wide range of applications. The dual - acting design of 2710-100 series grips means that jaw faces can be adjusted to accommodate different specimen thicknesses. This ensures that the line of tensile force remains concentric with the grip body. They can be equipped with a selection of interchangeable grip jaw faces in various sizes and choice of surfaces including smooth ground, rubber-coated and serrated. Line contact and special coated faces are also available.The unique ‘snap-on’ jaw face attachment makes changing faces extremely quick and simple.

  • Products
  • 6/28/2017
  • 1.3 MB

Region Selector

Dismiss Region Selector

Americas

  • North America
  • Brasil
  • South America

All Other Countries

  • Global Site

Europe

  • France
  • Deutschland
  • Italia
  • Polska
  • España
  • Türkçe
  • United Kingdom

Asia Pacific

  • 中国
  • India
  • 日本
  • 대한민국
  • 台灣
  • ประเทศไทย
Instron Logo White
Dane kontaktowe

Dział handlowy: +48 603 779 585

Serwis: +48 691 016 100

PRZYDATNE LINKI
  • Systemy testujące
  • Oprogramowanie
  • Akcesoria
  • Katalog
  • Słownik
  • Biblioteka
  • Rozwiązania do badań i testów
  • Newsletter
  • Webinaria
  • Studia przypadku
  • Wydarzenia
  • Kariera
Policies / Legal
  • Polityka prywatności i plików cookie
  • Warunki korzystania
  • Dostępność
  • Kontrola eksportu
  • Informacja o danych RODO
Skontaktuj się z nami
ZAPISZ SIĘ DO NASZEGO NEWSLETTERA
ADRES E-MAIL
© Illinois Tool Works Inc. All rights reserved.
[email protected]
  • Polityka prywatności i plików cookie
  • Warunki korzystania
  • Dostępność
  • Kontrola eksportu
  • Informacja o danych RODO